3512A (50 Hz) Standard Equipment

Air Inlet
  • Air cleaner; single element canister type with service indicator

Control Panel
  • EMCP4.2 controls including: Emergency stop pushbutton
  • EMCP4.2 controller including:
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Controls:
  • Speed adjust
  • Auto / start / stop control
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over/Under voltage (27/59)
  • Over/Under Frequency (81 o/u)
  • Reverse Power (kW) (32)
  • Reverse Reactive Power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Communications
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • 6 programmable digital inputs
  • 4 programmable relay outputs (Form A)
  • 2 programmable relay outputs (Form C)
  • 2 programmable digital outputs

Cooling
  • JWAC.
  • Radiator fan and fan drive
  • Fan and belt guards.
  • Coolant drain line with valve
  • Coolant level sensors. (Not included with packages without radiator)
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)

Exhaust
  • Dry Exhaust Manifold
  • Flanged faced outlet(s)

Fuel
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump

Generators and Attachments
  • 3 phase brushless, salient pole
  • 6 lead
  • Generator set packages include: Regulator (CDVR)
  • Caterpillar's Digital Voltage Regulator (CDVR) includes:
  • Reactive droop capability
  • 3 Phase voltage sensing
  • KVAR/PF modes
  • RFI suppression
  • Min / max exciter limiter
  • Exciter diode monitor
  • LV:
  • Random wound
  • Internal Excitation
  • NEMA Class H insulation
  • Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Winding temperature detectors
  • Busbar connections, top center mounted, top cable entry
  • 50 Hz models: IEC standard hole pattern
  • Note: 1800 frames are form wound, permanent magnet, with winding temp detectors

Governing System
  • Woodward 2301A isochronous governor

Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal

Mounting System
  • Rails - engine/generator/radiator mounting
  • Rubber anti-vibration mounts (shipped loose)

Starting / Charging System
  • 24-volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

General
  • Paint - Caterpillar Yellow with high gloss black rails & radiator
  • RH Service
  • Flywheel and Flywheel housing-SAE No. 00
  • SAE Standard Rotation

3512A (50 Hz) Optional Equipment

Air Inlet System
  • Dual Element air cleaners
  • Remote air inlet adaptors
  • Air Inlet protection

Circuit Breakers
  • Optional busbar power connections
  • Breaker harnesses
  • Center posts busbars
  • Cable entry options
  • Controls packaging - Enclosures
  • EMAX circuit breakers
  • 2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated circuit breakers
  • 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated circuit breakers
  • Busbar connections
  • EMAX breakers connections

Control Panels
  • EMCP 4.3
  • EMCP 4.4
  • Customer connection mounting locations
  • Annunciator Modules
  • Governors
  • Mounting Group - External Box Clips
  • Auxiliary Boxes
  • Customer Interface Options
  • Generator Temperature Monitoring
  • Remote speed adjust
  • Vandle proof panel door
  • Local PC monitoring
  • Ground (Automatically selected)

Cooling System
  • Optional radiator arrangements
  • Water level switch gauges
  • Heat exchangers

European Certifications
  • European Union Certification
  • EU declaration of conformity
  • Eurasian conformity (EAC) mark
  • European directive genset, DoI (Declaration of Incorporation)

Exhaust System
  • Mufflers
  • Muffler mounting kits
  • Flexible fittings
  • Through-wall installation kit

Fuel System
  • Primary fuel filter

Generators and Attachments
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, internal excitation, No. of leads = 6, pitch= 0.6667
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, permanent magnet, No. of leads = 6, pitch= 0.6667
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, form wound, permanent magnet, No. of leads = 6, pitch= 0.6667
  • Generator conversion
  • Space heater

Instrumentation
  • Pyrometer and thermocouples

Lube System
  • Oil level Reg-1 shallow pan
  • Electric prelube pumps
  • Manual prelube sump pumps

Mounting System
  • Spring-type vibration isolator
  • IBC vibration isolators

Protection System
  • Explosion relief valve

Special Tests / Reports
  • Neutral grounding connection
  • Neutral ground-LV
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.80 power factor
  • IBC seismic certifications

Starting / Charging Systems
  • 10 Amp battery chargers
  • 20 Amp battery charger
  • Oversize battery set
  • 24 Volt dual electric starting motor
  • Ether starting aid
  • Jacket water heaters

General
  • Engine barring group

Overview

Producing reliable power from 1000 kVA to 1400 kVA ekW at 50 Hz, our 3512 diesel generator sets are engineered for your mission critical, continuous, standby and prime applications. Each meet ISO 8528-5 transient response requirements and accept 100 percent rated load in one. And each is designed for low fuel consumption reducing operating costs. Our integrated control system, including Cat® UPS, ATS and switchgear, secure your power supply and keep you connected to your fleet through on-site and remote monitoring. Our EMCP4 control panel provides a flexible control platform, with an easy-to-use display — it’s your single source for management and diagnostics tools. We know it’s not just quality that matters but customization. Choose from a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging options to work with your spatial restrictions and environment conditions.

Generator Set Specifications

Units:
Minimum Rating 1000kVA 1000kVA Less
Maximum Rating 1400 kVA 1400 kVA Less
Voltage 220 to 13800 Volts 220 to 13800 Volts Less
Frequency 50 Hz 50 Hz Less
Speed 1500 RPM 1500 RPM Less

Generator Set Configurations

Emissions/Fuel Strategy Low Fuel Consumption Low Fuel Consumption Less

Engine Specifications

Engine Model 3512 TA, V-12, 4-Stroke Water-Cooled Diesel 3512 TA, V-12, 4-Stroke Water-Cooled Diesel Less
Compression Ratio 13.5:1 13.5:1 Less
Aspiration TA TA Less
Governor Type Woodward Woodward Less
Fuel System Direct Unit Injection Direct Unit Injection Less
Bore 6.69 in 170.0 mm Less
Displacement 3161.03 in3 51.8 L Less
Stroke 7.48 in 190.0 mm Less

Cat™ Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
  • Cat EMCP Control Panel

    The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

    Design Criteria

    The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

    UL 2200 / CSA - Optional

  • UL 2200 listed packages
  • CSA Certified
  • Certain restrictions may apply.
  • Consult with your Cat® Dealer.
  • Single-Source Supplier

    Fully prototype tested with certified torsional vibration analysis available

    World Wide Product Support

    Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

    Customer Stories

    Discover what’s new and how customers like you are benefiting from our products and services. Check back often for updates.

    Learn More
    Promotions

    Looking for that perfect piece of used equipment to complement your fleet? Check out our Used Exclusives, featuring new machines every week!

    Learn More
    Social

    Let’s talk. Connect with us on one of our social channels to start the conversation and see what we’re up to.

    Learn More
    Branch Locator

    Looking for your nearest branch? Get in touch with us today by contacting one of our branches directly. We’re always ready to help.

    Learn More
    Services

    When you choose Finning, you have a wide array of support and specialty services to help you get the most from your equipment.

    Learn More
    Technology

    Integrated technology can help you understand your equipment's output and help extend its lifespan.

    Learn More
    Finance

    Choose from a range of financing solutions that allow you to purchase equipment, parts, services, and technology when you need it.

    Learn More

    Please share your feedback on Finning.com!

    Close window

    We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

    Thank you in advance for your time!