Menu

C27 (60 Hz) Tier 4 Interim

Back


View Product Downloads

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Units:
Minimum Rating 725 ekW 725 ekW Less
Maximum Rating 800 ekW 800 ekW Less
Voltage 208 to 600 208 to 600 Less
Frequency 60 Hz 60 Hz Less
Speed 1800 RPM 1800 RPM Less

Generator Set Configurations

Emissions/Fuel Strategy EPA Tier 4 Interim EPA Tier 4 Interim Less

Engine Specifications

Engine Model C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Less
Compression Ratio 16.0:1 16.0:1 Less
Aspiration TA TA Less
Governor Type Adem™A4 Adem™A4 Less
Fuel System MEUI MEUI Less
Bore 5.4 in 137.2 mm Less
Displacement 1649.47 in³ 27.03 L Less
Stroke 6.0 in 152.4 mm Less

Cat™ Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
  • Cat EMCP Control Panel

    The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

    World Wide Product Support

    Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

    Design Criteria

    The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

    UL 2200 / CSA - Optional

  • UL 2200 listed packages
  • CSA Certified
  • Certain restrictions may apply.
  • Consult with your Cat® Dealer.
  • Single-Source Supplier

    Fully prototype tested with certified torsional vibration analysis available

    C27 (60 Hz) Tier 4 Interim Standard Equipment

    Air Inlet
    • Single element canister type with service indicator

    Control Panel
    • EMCP 4 / EMCP 4.2B Genset Controllers
    • EMCP 4.2B Control Features
    • Digital Indicators
    • Warning/shutdown Indicators
    • Programmable Protective Relaying Functions
    • Communications

    Cooling
    • ATAAC
    • Radiator sized to 50 degrees C (122 degrees F)
    • Coolant drain line with valve terminated on edge of base
    • Fan and belt guards drive
    • Coolant level sensor
    • Caterpillar Extended Life Coolant

    Exhaust
    • Exhaust Manifold - dry
    • 203mm (8in) ID round flanged outlet

    Fuel
    • Primary fuel filter with water separator
    • Secondary fuel filters
    • Fuel cooler
    • Flexible fuel lines - installed
    • Electric fuel priming pump

    Generator and Attachments
    • SR5 Permanent Magnet (PM)
    • For Low BSFC configurations:
    • Integrated Voltage Regulator (IVR) includes
    • Bus bar connections:

    Lube System
    • Lubricating oil
    • Standard volume oil pan - 68 Ltr
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal - open crankcase ventilation routed to front of package

    Mounting System
    • Rails - engine/generator/radiator mounting
    • Rubber anti-vibration mounts - shipped loose

    Starting and Charging System
    • 24-volt electric starting motor
    • Charging Alternator 45A
    • Battery, rack and cables - shipped-loose
    • Battery disconnect switch

    General
    • Paint: Caterpillar Yellow with high gloss black rails & radiator
    • RH Service
    • Flywheel and flywheel housing-SAE No. 0 and SAE No. 18
    • SAE Standard Rotation

    C27 (60 Hz) Tier 4 Interim Optional Equipment

    Air Inlet System
    • Standard air cleaners
    • Dual element air cleaners
    • Heavy duty air cleaners

    Battery / Charging System
    • 10 Amp battery chargers
    • 20 Amp enclosure battery chargers
    • 24 Volt battery sets - Dry
    • 24 Volt electric start motors - Heavy duty
    • Jacket water heaters
    • Air starting motor with control and silencer
    • Space heater

    Circuit Breakers
    • 400, 800, 1200, 1600, 2000, 2500, 3000 Amp, 3 pole, UL-100% rated circuit breakers
    • 2000 Amp, 3 pole, IEC rated circuit breakers
    • 800 Amp, 4 pole, IEC rated circuit breakers

    Control Panels
    • EMCP (4.2B) (4.3) (4.4)
    • Remote mounting harness
    • Remote mounted circuit breaker terminals
    • Remote mounted panel harness mounting kit
    • Auxiliary box options
    • Side extension box
    • Cable shroud - Top mounted
    • Cable shroud - Bottom mounted
    • Cat connect telematics
    • Installed DIO module
    • Remote DIO module
    • Annunciator modules
    • Remote annunciator modules
    • Modbus monitor local packages
    • Load share module
    • Vandal proof panel cover

    Cooling System
    • Standard radiator
    • High ambient radiator
    • Certified radiator
    • Extended life coolant
    • Radiator duct flange

    Enclosures
    • Special sound attenuated enclosure
    • Enclosure with lifting base or fuel tank
    • Enclosure fuel tank options
    • Enclosure louvers
    • Cold weather bundle
    • Enclosure lighting
    • AC distribution panel, lights and outlet
    • Panel bracket
    • Enclosure colors

    Exhaust
    • Flanges
    • Guard and shield system
    • Elbows
    • Flexible fittings
    • Mufflers
    • Exhaust through the wall kit

    Generator and Attachments
    • 60 Hz standard generators
    • 60 Hz premium generators

    Lube System
    • Oil level regulator
    • Prelube pumps

    Mounting System
    • Puck style low efficiency isolators
    • Spring-type vibration isolator
    • IBC vibration isolators
    • Mounting base type

    Power Connections
    • Neutral grounding connection
    • Center post busbar
    • Power connections - Right / Left / Rear
    • Cable entry - Right / Left / Rear

    Starting/Charging
    • Battery chargers
    • Oversize batteries
    • Jacket water heater
    • Heavy-duty starting system
    • Charging alternator
    • Air starting motor with control and silencer

    Special Tests / Reports
    • IBC Seismic certifications
    • OSHPD Seismic certifications
    • Special CSA test cerification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Generator test report
    • Standard engine test
    • Torsional vibration analysis report

    General
    • Special paint
    • US aid emblem
    • Miscellaneous inspection
    • EU Certificate of Conformance (CE)

    News & Events

    View the latest company and product news, events and customer stories.

    Learn More
    Promotions

    View the latest offers available on a range of Cat® equipment and genuine parts.

    Learn More
    Social Media

    Connect with us to learn more about our company, products, services and customers.

    Learn More
    Branch Locations

    With branches across the UK & Ireland, you can be sure that we’re never far away.

    Learn More
    Services

    Effectively manage your equipment to reduce operating costs and improve efficiency.

    Learn More
    Technology

    Integrated technology can help you understand your equipment's output and help extend its lifespan.

    Learn More
    Finance

    Quick and easy financing with customised payment plans through Cat Financial.

    Learn More