C175-16 Tier 4 Final (60 Hz) Standard Equipment

Air Inlet System
  • Air Cleaner; 4 x single element canister with service indicator(s).

Control Panel
  • EMCP4.3 controls including emergency stop button
  • EMCP4.3 controller including:
  • - 24-volt DC operation.
  • - Environmental sealed front face
  • - Text alarm/event descriptions
  • - Warning/shutdown with common LED indication of shutdowns with indicating lights for:
  • - Low oil pressure
  • - High coolant temperature.
  • - Overspeed
  • - Emergency stop.
  • - Failure to start (overcrank)
  • - Low coolant level (requires optional coolant sensor)
  • Generator mounted - rear facing.
  • Controls:
  • - Speed adjust
  • - Auto/start/stop control.
  • - Engine cool-down timer
  • - Engine cycle crank
  • - Alarm acknowledge
  • - Lamp test
  • - True RMS AC metering, 3-phase, +/-0.25% accuracy
  • Digital indication for:
  • - RPM
  • - DC volts
  • - Operating hours
  • - Coolant temperature
  • - Volts (L-L & L-N
  • - Frequency (Hz).
  • - Amps (per phase & average).
  • - Power Factor (per phase & average)
  • - kW (per phase, average & percent)
  • - kVA (per phase, average & percent)
  • - kVAr (per phase, average & percent)
  • - kW-hr (total)
  • - kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for:
  • - Low oil pressure
  • - High coolant temperature
  • - Overspeed
  • - Emergency stop
  • - Failure to start (overcrank)
  • - Low coolant temperature
  • - Low coolant level
  • Programmable protective relaying functions:
  • - Generator phase sequence
  • - Over / Under voltage (27/59)
  • - Over / Under frequency (81 o/u)
  • - Reverse power (kW) (32)
  • - Reverse reactive power (kVAr) (32RV)
  • - Overcurrent (50/51)
  • Communications:
  • - Customer data link (Modbus RTU)
  • - Accessory module data link
  • - Serial annunciator module data link
  • - 6 programmable digital inputs
  • - 4 programmable relay outputs (Form A
  • - 2 programmable relay outputs (Form C)
  • - 2 programmable digital outputs
  • - 12 programmable digital inputs
  • - 16 programmable digital outputs
  • - 3 programmable analog inputs
  • - 3 programmable analog outputs
  • - 2 programmable PWM outputs
  • Local annunciator option

Cooling System
  • SCAC cooling
  • Radiator group shipped loose.
  • Fan and belt guards
  • Coolant drain line and valves
  • Coolant sensor - (2 x shipped loose: 1/4-18 and 1/2-14 NPTF).

Exhaust System
  • Insulated CEM
  • CEM dosing module
  • CEM dosing module features:
  • - Air filter
  • - DEF filter
  • - 120VAC
  • - Freeze protection
  • - DEF line purge
  • - External relay
  • Harness from dosing module to CEM
  • Air and heated DEF lines from dosing module to CEM
  • Dry exhaust manifold
  • Flanged faced outlets at CEM in (21.2") and out (25")

Fuel System
  • Primary fuel filter water / fuel water separator
  • 10 Micron spin on type
  • 3 Filters, shipped loose - can be mounted on frame rails (Requires dealer provided flex)
  • Secondary / tertiary fuel filters
  • 4 Micron Spin On Type
  • 3 Filters, engine mounted

Generator and Attachments
  • 3 Phase brushless, salient pole
  • 6 lead
  • IEC platinum stator RTDs (.00385 temperature coefficient)
  • Caterpillar's digital voltage regulator (CDVR) includes:
  • - Reactive droop capability
  • - 3-Phase voltage sensing
  • - KVAR / PF modes
  • - RFI suppression
  • - Min / Max exciter limiter
  • - Exciter diode monitor
  • 1800 Frame generators (LV/MV)
  • Form wound
  • NEMA Class H insulation
  • Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • (LV) Bus bar connections, top / center mounted, top cable entry
  • - 60 Hz models: NEMA standard hole pattern
  • (MV)Bus bar connections, right side extension box, bottom cable entry
  • - 60 Hz models: NEMA standard hole pattern.
  • 3000 Frame generators (MV/HV)
  • Form wound
  • Permanent magnet
  • Anti condensation space heater
  • NEMA Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Right side extension box, bottom cable entry

Governing System
  • ADEM A4
  • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
  • Prelube - required with prime and continuous; optional with standby

Mounting System
  • Rails - Engine / Generator
  • Rubber anti-vibration mounts (shipped loose).
  • Dual 24-volt electric starting motors
  • Batteries and battery rack w/cables
  • Battery disconnect switch

Service Instructions
  • Two PM Inspections

General
  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • RH Service (except oil filter service 60 Hz models: left hand service
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation
  • *For HV EMCP4.3 control panel: Includes wall mount control panel, shipped loose, for customer mounting and 7.5 meter interconnect harness.
  • * For HV applications, customer to provide 120V secondary sensing, 5A secondary current sensing and harness between package and EMCP4.3 (drawing provided). CDVR is installed in wall mount.

C175-16 Tier 4 Final (60 Hz) Optional Equipment

Air Inlet System
  • Single stage air cleaner

Control Panels
  • EMCP 4.3
  • EMCP 4.4 requires 1800 frame low voltage packages
  • E-Stop - Only for use with 3000 frame generators and EMCP4.3
  • Load share module
  • EMCP mounting location - LV / MV -- requires 1800 frame generator
  • Customer AC-DC connection mounting location - LV / MV
  • Load share governor / auxiliary plate and auxiliary box (LV)
  • Remote speed adjust
  • Annunciator modules
  • Customer interface options
  • Generator temperature monitoring
  • Modbus monitoring of packages
  • Vandal proof panel door

Cooling System
  • Package mounted radiator
  • Remote radiators
  • SCAC circuits
  • Fuel cooler

Exhaust
  • Exhaust collectors / manifold

Fuel System
  • Primary fuel filter

General
  • Paint - colors (other than Caterpillar yellow) or high performance paints
  • US aid emblem

Generator and Attachments
  • 480 Volts, Generators (LV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 - 1800 frame
  • 480 Volts, Generators (MV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 -- 1800, 3000 frame
  • Space heater kit
  • Thermostat for space heater
  • Differential current transformers (DCT):
  • - 5, 9 and 15 kV class DCTs

Instrumentation
  • Pyrometer and thermocouples
  • Harness - ECM interconnect

Lube System
  • Lube oil heater
  • Oil pan drain valve
  • Standard sump oil pan
  • Lubricating oil
  • Electric prelube pump
  • Oil filters

Crankcase Systems
  • Explosion relief valves

Mounting System
  • Rubber anti-vibration mounts
  • Spring-type linear vibration isolators
  • IBC vibration isolators - shipped loose

Power Connections
  • Center post busbars (LV) connections
  • Side / Rear monted busbars (LV)
  • Cable entry options (LV)
  • Control packating (LV) - Enclosures
  • Power connection covers
  • Optional package mounted circuit breakers (LV)
  • 4000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
  • 4000 Amp, 3 Pole, IEC-Rated Circuit Breakers
  • 5000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
  • 5000 Amp, 3 Pole, IEC-Rated Circuit Breakers
  • Circuit Breaker Harness
  • MV Power Connection Options:
  • - 1800 Frame generator side / rear mounted busbars:
  • - Left hand MV nema busbar
  • - Right hand MV nema busbar
  • Cable entry options - 1800 frame (MV)
  • Neutral ground - (MV)
  • Masterpack breaker connections

Service Tools - Barring Groups
  • Engine group
  • Group manual
  • Engine air powered
  • Control GP-airpowered group

Special Tests / Reports
  • Generator test report
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Standard genset torsional nibration analysis (TVA) report
  • Custom genset TVA report
  • Fuel consumption test
  • Standard engine test charge

Starting/Charging
  • 24 Volt power distribution box
  • 24 Volt electric starting motor
  • Air starting motor
  • Covers - starter locations
  • 24 Volt battery set - dry
  • Heavy duty battery set with rack
  • 35 and 50 Amp battery chargers
  • Jacket water heaters
  • Jacket water heater wiring groups

Overview

2500 to 3000 ekW (3100 ekW without fan) in 60 Hz 1800 RPM configurations that deliver 480 to 13800 Volts for Continuous, Prime, Mission Critical and Standby applications.

Generator Set Specifications

Units:
Minimum Rating 2500 ekW 2500 ekW Less
Maximum Rating 3100 ekW 3100 ekW Less
Voltage 480 - 13800 Volts 480 - 13800 Volts Less
Frequency 60 Hz 60 Hz Less
Speed 1800 RPM 1800 RPM Less

Generator Set Configurations

Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Stationary Genset U.S. EPA Certified for Non-Emergency Stationary Genset Less

Engine Specifications

Engine Model C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel Less
Compression Ratio 50 Hz 16:7:1 16:7:1 Less
Compression Ratio 60 Hz 15:3:1 15:3:1 Less
Aspiration Turbo Aftercooled Turbo Aftercooled Less
Governor Type ADEM™ A4 ADEM™ A4 Less
Fuel System Common Rail Common Rail Less
Bore 8.89 in 175.0 mm Less
Displacement 5155.88 in³ 84.67 L Less
Stroke 8.66 in 220.0 mm Less

Cat™ Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
  • Cat EMCP Control Panel

    The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

    Cat Clean Emissions Module (CEM)

    Diesel oxidation catalyst for particulate matter(PM) and hydrocarbon(HC) control Selective catalytic reduction (SCR) with integrated sound attenuation Integrated electronics for monitoring, protection, and closed loop NOx control. Reliable, compact, and lightweight system gives maximum installation flexibility

    Design Criteria

    The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

    Full Range of Attachments

    Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation

    Single-Source Supplier

    Fully prototype tested with certified torsional vibration analysis available

    World Wide Product Support

    Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

    News & Events

    View the latest company and product news, events and customer stories.

    Learn More
    Promotions

    View the latest offers available on a range of Cat® equipment and genuine parts.

    Learn More
    Social Media

    Connect with us to learn more about our company, products, services and customers.

    Learn More
    Branch Locations

    With branches across the UK & Ireland, you can be sure that we’re never far away.

    Learn More
    Services

    Effectively manage your equipment to reduce operating costs and improve efficiency.

    Learn More
    Technology

    Integrated technology can help you understand your equipment's output and help extend its lifespan.

    Learn More
    Finance

    Quick and easy financing with customised payment plans through Cat Financial.

    Learn More

    Please share your feedback on Finning.com!

    Close window

    We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

    Thank you in advance for your time!