The D550 GC (60 Hz)diesel generator sets were developed to meet your needs in a standby application. Producing reliable power from 500 to 550 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step. Our D550 GC generator sets meet EPA Stationary Emergency (Tier 2) certified emissions requirements.
Compare Models
Generator Set Specifications
Minimum Rating
550 ekW
550 ekW
Maximum Rating
600 ekW
600 ekW
Emissions/Fuel Strategy
U.S. EPA Certified
U.S. EPA Certified
Voltage
480 to 600 Volts
480 to 600 Volts
Frequency
60 Hz
60 Hz
Speed
1800 rpm
1800 rpm
Duty Cycle
Standby
Standby
Engine Specifications
Engine Model
Cat® C18 ATAACTM In-line 6, 4-cycle diesel
Cat® C18 ATAACTM In-line 6, 4-cycle diesel
Bore
5.71 in
145.0 mm
Stroke
7.2 in
183.0 mm
Displacement
1106.3 in³
18.1 l
Compression Ratio
14.5:1
14.5:1
Aspiration
Air to Air Aftercooled
Air to Air Aftercooled
Fuel System
Electronic unit injection
Electronic unit injection
Governor Type
Electronic ADEM™ A4
Electronic ADEM™ A4
Generator Set Dimensions
Length - Maximum
196.1 in
4980.0 mm
Width - Maximum
73.4 in
1865.0 mm
Height - Maximum
100.9 in
2563.0 mm