C13 (50 Hz)

Select Units

Overview

350 to 450 kVA Generator Set for Emergency Standby (ESP), Standby, Prime and Continuous applications

Generator Set Specifications

  • Minimum Rating 350 kVA 350 kVA
  • Maximum Rating 450 kVA 450 kVA
  • Voltage 380 to 415 Volts 380 to 415 Volts
  • Frequency 50 Hz 50 Hz
  • Speed 1500 RPM 1500 RPM

Generator Set Configurations

  • Emissions/Fuel Strategy Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards

Engine Specifications

  • Engine Model C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
  • Compression Ratio 16.3:1 16.3:1
  • Aspiration Air to Air Aftercooled Air to Air Aftercooled
  • Governor Type Adem™A4 Adem™A4
  • Fuel System MEUI MEUI
  • Bore 5.12 in 130.0 mm
  • Displacement 762.8 in³ 12.5 l
  • Stroke 6.18 in 157.0 mm

C13 (50 Hz) Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable paper filter
  • Aftercooler core
  • Turbocharger

Control Panel

  • EMCP 4.2

Cooling System

  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar Extended Life Coolant

Exhaust System

  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose

Fuel System

  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generator and Attachments

  • A frame generator - IP21 Protection
  • Optional LC frame generator - IP23 Protection
  • Integrated Voltage Regulator
  • Power center, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre

Governing System

  • Cat Electronic Governor (ADEM A4)

Lube System

  • Oil Cooler
  • Lubricating oil
  • Oil drain valves

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines

Starting / Charging System

  • 24V battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

C13 (50 Hz) Optional Equipment

European Certificates

  • EU certificate of conformance
  • Global certificate for CIS

Air Inlet System

  • Single element air cleaner
  • Dual element air cleaner

Circuit Breakers

  • 3 Pole (IEC-100% rated) circuit breaker
  • 4 Pole (IEC-100% rated) circuit breaker
  • 3 Pole (IEC-100% rated) circuit breaker - Motorised
  • 4 Pole (IEC-100% rated) circuit breaker - Motorised
  • Circuit breaker (IEC) auxiliary contacts
  • Shunt trip for IEC circuit breaker
  • Pad-lockable circuit breaker device
  • Power terminal strip

Control Panels

  • Volt free contacts
  • EMCP 4.3, EMCP 4.4
  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • Local alarm modules: Local annunciator
  • Remote annunciator modules

Cooling System

  • Radiator duct flange
  • Stone guards
  • Low coolant temperature alarm

Enclosures

  • Sound attenuated enclosures
  • High ambient sound attenuated enclosures

Exhaust System

  • Mufflers - End in / End out
  • 10, 25 and 35 dBA attenuation
  • 6 and 8 inch flange GP
  • Flexible 8 inch exhaust fittings
  • 6 and 8 inch elbow kit

Fuel System

  • Integral dual wall fuel tank base
  • Manual fuel transfer pump
  • Fuel transfer system controls

Generator and Attachments

  • Ingress protection
  • Permanent magnet generator
  • Space heaters
  • A frame oversize generator
  • A frame CIP generator
  • LC frame generator
  • LC CIP generator

Lube System

  • Manual sump pump

Mounting System

  • Narrow skid base

starting / Charging System

  • 5 Amp single battery charger
  • Battery disconnect switch
  • Jacket water heater

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
  • Cat EMCP Control Panel

    The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP 4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP 4 systems can be further customized to meet your needs through programming and expansion modules.

    Design Criteria

    The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

    World Wide Product Support

    Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

    News & Events

    View the latest company and product news, events and customer stories.

    Promotions

    View the latest offers available on a range of Cat® equipment and genuine parts.

    Social Media

    Connect with us to learn more about our company, products, services and customers.

    Branch Locations

    With branches across the UK & Ireland, you can be sure that we’re never far away.

    Services

    Effectively manage your equipment to reduce operating costs and improve efficiency.

    Technology

    Integrated technology can help you understand your equipment's output and help extend its lifespan.

    Finance

    Quick and easy financing with customised payment plans through Cat Financial.

    Please share your feedback on Finning.com!

    Close window

    We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

    Thank you in advance for your time!