Producing reliable power from 1600 kVA to 1750 kVA at 50 Hz and 830 ekW to 1000 ekW at 60 Hz, our C32 ACERT™ diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. Our integrated control system keeps you connected through on-site and remote monitoring options. We offer easy-to-use EMCP control panel options, combining your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to match your growing power requirements. Browse a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit unique spatial requirements and environmental conditions. Our C32 generator sets are made for demands, so you can make yours. broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit unique spatial requirements and environmental conditions. Even extend the safety of your operation with UL 2200 and CSA certified package options. Our C32 generator sets are made for demands, so you can make yours.

Generator Set Specifications

  • Minimum Rating 830 ekW (910 kVA) 830 ekW (910 kVA)
  • Maximum Rating 1000 ekW (1250 kVA) 1000 ekW (1250 kVA)
  • Voltage 220 to 4160 220 to 4160
  • Frequency 50 or 60 Hz 50 or 60 Hz
  • Speed 1500 or 1800 RPM 1500 or 1800 RPM

Generator Set Configurations

  • Emissions/Fuel Strategy Low Fuel Consumption, Low Emissions Low Fuel Consumption, Low Emissions

Engine Specifications

  • Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel C32 TA, V-12, 4-Stroke Water-Cooled Diesel
  • Bore 145 mm (5.71 in) 145 mm (5.71 in)
  • Displacement 32.1 L (1958.86 in3) 32.1 L (1958.86 in3)
  • Stroke 162 mm (6.38 in) 162 mm (6.38 in)
  • Compression Ratio 15.0:1 15.0:1
  • Aspiration TA TA
  • Governor Type Adem™A4 Adem™A4
  • Fuel System MEUI MEUI
  • Exhaust Flange Size - Internal Diameter 203.2 mm (8.0 in) 203.2 mm (8.0 in)
  • Air Inlet Single element canister style with service indicator Single element canister style with service indicator

3516B with Flexible Packaging Standard Equipment

Air Inlet System

  • Air Cleaner; single element canister type

Control Panels

  • EMCP4
  • Emergency stop pushbutton
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm/event descriptions
  • Generator mounted - rear facing
  • Generator set packages include Caterpillar' s Voltage Regulator . IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for: RPM - DC volts - Operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - k
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
  • Programmable protective relaying functions: Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kW) (32) - Reverse Reactive Power (kVAr) (32RV) - Overcurrent (50/51)
  • Communications: Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Cat Connect - 3 Analog inputs - 6 Customer programmable digital inputs
  • Number of I/O varies on options selected: 4 programmable relay outputs (Form A) - 1 programmable relay outputs (Form C) - 1 programmable digital outputs

Cooling System

  • Certified standard PGS provided
  • ATAAC - 3516E Package Radiators shipped installed

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump

General

  • Caterpillar yellow with high gloss black rails and radiator
  • Right hand servicing
  • Flywheel and flywheel housing - SAE No. 00
  • SAE Standard rotation

Generator and Attachments

  • 3 Phase brushless, salient pole
  • 6 lead
  • Low Voltage: Random wound - Internal Excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pa
  • Medium Voltage: Form wound - Permanent magnet - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Bus bar connections, right side extension box, bottom cable entry - NEMA standard
  • High Voltage: Form wound - Permanent magnet - Winding temperature detectors - Anti Condensation Space Heater - Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

Governing System

  • ADEM A3

Literature

  • English

Lubrication System

  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cool
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal

Mounting System

  • Rails - engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts (shipped loose)

Starting System

  • 24 Volt electric starting motor
  • 45 Amp charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch

3516B with Flexible Packaging Optional Equipment

Control System

  • EMCP4.2B, EMCP4.3 and EMCB4.4

Air Inlet System

  • Single element filter
  • Dual element air cleaner

Cooling System

  • Standard ambient radiators
  • Standard ambient ATAAC radiators
  • Optional installed radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Coolant

Crankcase System

  • No explosion relief valves
  • Explosion relief valves
  • Ventilation system

Exhaust System

  • Elbows
  • Flange and exhaust expanders
  • Flanges
  • Flexible fittings
  • Y-Adapters
  • Mufflers
  • Exhaust offset
  • Tier 4 clean emissions module
  • Tier 4 dosing cabinet
  • Tier 4 clean emission MOD Kits
  • Clean emission parts

Fuel System

  • Primary Fuel Filter
  • Fuel Priming Pumps (Tier 4) - Manual or Electric

General

  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

  • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
  • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Space heater
  • Generator conversion
  • Thermostate for space heater
  • Alternator air cleaner
  • Differential current transformers (DCT)
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes

Instrumentation

  • Pyrometer and Thermocouples

Lubrication System

  • Lube oil in standard sump
  • Oil level regulator
  • Prelube pumps

Mounting System

  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators

Power Connections

  • Ground cables between generator and terminal box
  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Left side power connections
  • Rear power connections
  • 2700 Frame, four lead, four terminal
  • Low voltage circuit breakers

Special Tests / Reports

  • Canadian Standards Association certification
  • IBC certification
  • OSHPD certification
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Standard engine test charge
  • generator test report
  • Fuel consumption test
  • Generator set fuel consumption test
  • Torsional vibration analysis reports

Starting and Charging

  • Engine barring device
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 amp battery chargers
  • Electric starting motors
  • Air starting motors
  • Starter cover
  • Air pressure regulator
  • Jacket water heaters

Extended Service Coverage

  • Platinum, Gold and Silver coverage

News & Events

View the latest company and product news, events and customer stories.

Promotions

View the latest offers available on a range of Cat® equipment and genuine parts.

Social Media

Connect with us to learn more about our company, products, services and customers.

Branch Locations

With branches across the UK & Ireland, you can be sure that we’re never far away.

Services

Effectively manage your equipment to reduce operating costs and improve efficiency.

Technology

Integrated technology can help you understand your equipment's output and help extend its lifespan.

Finance

Quick and easy financing with customised payment plans through Cat Financial.

Please share your feedback on Finning.com!

Close window

We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

Thank you in advance for your time!