Menu

3516E (50 Hz)

Select Units

Overview

The 3516E diesel generator sets are made to match your mission critical, standby and prime applications, and meet our quality standards. Producing reliable power from 2750 to 3000 kVA (3100 kVA without fan) at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. Seismic certification is also available for select models, maintaining power after unexpected disturbances. The integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. With an user friendly interface our EMCP 4 control panel provides flexible options putting your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to provide expanded capacity and generator set redundancy to match your requirements. As no two power requirements are the same we offer a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging options to work with your spatial requirements and environmental conditions. Our 3516E generator sets are developed for such prerequisites, so that you can meet your specific power needs — customize them to match your requirements.

Generator Set Configurations

  • Emissions/Fuel Strategy Low Fuel Consumption Low Fuel Consumption

Engine Specifications

  • Engine Model 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
  • Compression Ratio 14:01 14:01
  • Aspiration TA TA
  • Governor Type Adem™5 Adem™5
  • Fuel System Electronic unit injection Electronic unit injection
  • Bore 6.69 in 170.0 mm
  • Stroke - HD 8.46 in 215.0 mm

Generator Set Specifications

  • Minimum Rating 2750 kVA 2750 kVA
  • Maximum Rating 3000 kVA (3100 kVA without fan) 3000 kVA (3100 kVA without fan)
  • Voltage 380 to 11,000 volts 380 to 11,000 volts
  • Frequency 50 Hz 50 Hz
  • Speed 1500 rpm 1500 rpm
  • Height - Maximum 92.2 in 2342.0 mm
  • Length - Maximum 218.3 in 5545.0 mm
  • Width - Maximum 72.0 in 1828.0 mm

Design Criteria

The generator set accepts 100% rated load in one step per NFPA 110 and conforms to the ISO 8528-5:2013 G3 for load acceptance & steady state.

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
  • Cat EMCP Control Panel

    The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

    Single-Source Supplier

    Fully prototype tested with certified torsional vibration analysis available

    World Wide Product Support

    Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.

    Seismic Certification

  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010
  • 3516E (50 Hz) Standard Equipment

    Air Inlet System

    • Air cleaner
    • Single element canister type with service indicator

    Control Panel

    • EMCP 4.2
    • Emergency stop pushbutton
    • Panel lights
    • EMCP4.2 controller includes:
    • 24-volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Generator mounted - rear facing
    • Controls:
    • Speed adjust
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over / under voltage (27/59)
    • Over / under frequency (81 o/u)
    • Reverse power (kW) (32)
    • Reverse reactive power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • 6 programmable digital inputs
    • 4 programmable relay outputs (Form A)
    • 2 programmable relay outputs (Form C)
    • 2 programmable digital outputs

    Cooling System

    • JWAC
    • Radiator fan and fan drive
    • Fan and belt guards
    • Coolant drain line with valve
    • Coolant level sensors
    • Caterpillar Extended Life Coolant

    Exhaust System

    • Dry exhaust manifold
    • Flanged faced outlet(s)

    Fuel System

    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump

    Generators and Attachments

    • 3 phase brushless, salient pole
    • 6 lead
    • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
    • Random wound
    • Internal excitation
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).
    • Winding temperature detectors
    • Bus bar connections, top center mounted, top cable entry
    • IEC standard hole pattern

    Governing System

    • ADEM III

    Literature

    • English

    Lube System

    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal

    Mounting System

    • Rails - engine / generator / radiator mounting
    • Rubber anti-vibration mounts (shipped loose)

    Starting / Charging System

    • 24 Volt electric starting motor
    • Battery and battery rack w/cables
    • Battery disconnect switch

    General

    • Paint: Caterpillar yellow with high gloss black rails & radiator
    • Right hand servicing
    • Flywheel and flywheel housing-SAE No. 00
    • SAE standard rotation

    3516E (50 Hz) Optional Equipment

    Air Inlet System

    • Dual element air cleaners
    • Heavy duty air cleaners
    • Remote air inlet adapters
    • Air inlet protection

    Power Termination

    • Circuit breakers, IEC compliant

    Circuit Breakers

    • Optional busbar power connections
    • Load take off; IEC standard hole
    • Center posts busbars
    • Cable entry options
    • Control packaging for enclosures
    • Trip Units
    • EMAX breakers

    Control Panels

    • EMCP 4.3, EMCP 4.4
    • Language options
    • Busbar connections
    • EMAX breaker connections
    • Annunciator modules
    • Governors
    • External box clips
    • Auxiliary box
    • Customer interface options
    • Generator temperature monitoring
    • Voltage raise / lower switch
    • Remote speed adjust
    • Vandal proof panel door
    • Local and remote monitoring

    Cooling System

    • Optional Serpentine radiators
    • Water level switch gauges
    • Heat exchangers
    • Radiator duct flanges

    European Certifications

    • EU declaration of conformity

    Exhaust System

    • Mufflers
    • Muffler mounting kits
    • Flexible fittings
    • Through wall installation kit

    Fuel System

    • Primary fuel filter
    • Fuel coolers

    Generators and attachments

    • Optional generators
    • 3 Phase, Random wound, Internal excitation
    • Number of leads: 6
    • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
       
    • Random wound
    • Internal excitation
    • Pitch: 0.6667

    Instrumentation

    • Pyrometers and thermocouples

    Lube System

    • Oil level reg-1 shallow pan
    • Electric prelube pumps
    • Manual prelube sump pumps

    Mounting System

    • Spring type vibration isolators
    • IBC vibration isolators

    Protection System

    • Explosion relief valves

    Special Tests / Reports

    • CSA test and certification
    • Neutral ground certificate
    • IBC seismic certificate
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor

    Starting / Charging System

    • Charging alternators - 50 Amp
    • 10 and 20 amp battery chargers
    • 24 Volt battery sets - Dry
    • Dual 24 volt electric starting motors
    • ETHER starting aids
    • Jacket water heaters

    General

    • Engine barring group

    News & Events

    View the latest company and product news, events and customer stories.

    Promotions

    View the latest offers available on a range of Cat® equipment and genuine parts.

    Social Media

    Connect with us to learn more about our company, products, services and customers.

    Branch Locations

    With branches across the UK & Ireland, you can be sure that we’re never far away.

    Services

    Effectively manage your equipment to reduce operating costs and improve efficiency.

    Technology

    Integrated technology can help you understand your equipment's output and help extend its lifespan.

    Finance

    Quick and easy financing with customised payment plans through Cat Financial.

    Please share your feedback on Finning.com!

    Close window

    We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

    Thank you in advance for your time!