Menu

3412C (60 Hz)

Select Units

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

  • Minimum Rating 591 ekW 591 ekW
  • Maximum Rating 800 ekW 800 ekW
  • Voltage 208 to 600 Volts 208 to 600 Volts
  • Frequency 60 Hz 60 Hz
  • Speed 1800 RPM 1800 RPM

Generator Set Configurations

  • Emissions/Fuel Strategy Low Fuel Consumption Low Fuel Consumption

Engine Specifications

  • Engine Model 3412C TA, V-12, 4-Stroke Water-Cooled Diesel 3412C TA, V-12, 4-Stroke Water-Cooled Diesel
  • Compression Ratio 13:00:01 13:00:01
  • Aspiration TA TA
  • Governor Type ADEM™ A5 ADEM™ A5
  • Fuel System Pump and Lines Pump and Lines
  • Bore 5.4 in 137.2 mm
  • Displacement 1648.86 in³ 27.02 l
  • Stroke 6.0 in 152.4 mm

3412C (60 Hz) Standard Equipment

Air Inlet System

  • Air cleaner
  • Single element canister type

Control Panel

  • EMCP 4.2B
  • Controls:
  • - Run / Auto / Stop Control
  • - Speed Adjust
  • - Voltage Adjust
  • - Engine Cycle Crank
  • - Emergency stop pushbutton
  • Digital Indicator for:
  • - RPM
  • - DC volts.
  • - Operating hours.
  • - Oil pressure (psi, kPa or bar).
  • - Coolant temperature
  • - Volts (L-L & L-N)
  • - Frequency (Hz).
  • - Amps (per phase & average)
  • - Power Factor (per phase & average)
  • Warning shutdowns:
  • - Low oil pressure
  • - High coolant temperature
  • - Overspeed
  • - Emergency stop
  • - Failure to start (overcrank)
  • - Low coolant temperature
  • - Low coolant level
  • Communications:
  • - Customer data link (Modbus RTU)
  • - Accessory module data link
  • - Serial annunciator module data link
  • - Compatible with the following optional modules:
  • - Digital I/O module
  • - Local annunciator
  • - Remote CAN annunciator
  • - Remote serial annunciator
  • - Generator temperature monitoring module

Cooling System

  • Radiator with guard (sized for 50 degrees C).
  • Fan and belt guards
  • Coolant drain line with valve
  • Caterpillar extended life coolant

Exhaust System

  • Stainless steel exhaust flex with ANSI style outlet flange

Fuel System

  • Primary and secondary fuel filters
  • Fuel priming pump
  • Water separator

Generator and Attachments

  • SR4B self excited
  • Class H insulation
  • Class F temperature rise
  • 12 lead
  • VR6B Voltage Regulator
  • 3-phase sensing
  • 2:1 Volts/Hz.
  • Reactive droop
  • Busbar termination

Governing System

  • Cat electronic governor

Lube System

  • Lubricating oil
  • Oil filter
  • Oil drain line with valve

Mounting System

  • Base, formed steel with linear vibration isolators between base and engine-generator

Starting / Charging System

  • 45 amp charging alternator
  • Fuel shutoff solenoid
  • 24-volt starting motor
  • Battery with rack, cables

General

  • Paint - Caterpillar Yellow except rails and radiators gloss black

3412C (60 Hz) Optional Equipment

Air Inlet System

  • Air cleaner - dual element
  • Air cleaner - heavy element
  • Air cleaner - open element

Certificates

  • EU Certification

Circuit Breakers

  • 3-Pole Circuit Breakers with shunt trip
  • 4-Pole circuit breakerswith shunt trip
  • Power terminal strips

Control Panels

  • EMCP 4.3
  • EMCP 4.4
  • Common alarm / shutdown relay
  • Generator running VFC
  • Temperature monitoring package
  • Earth leakage ground fault relay
  • Vandal proof panel door

Cooling System

  • Radiator duct flange
  • Jacket water heater
  • Radiator removal

Exhaust

  • Muffler 10 dBA Attenuation
  • Muffler 35 dBA Attenuation
  • Elbow mounting kit
  • Through wall installation kit
  • Manifold and turbocharger Guard

Fuel System

  • Manual Fuel transfer pump
  • Automatic fuel transfer system

Generator and Attachments

  • Anti-condensation heater
  • Internal excitation (IE)
  • Permanent magnet excitation (PMG)
  • Oversize and premium generators

Governing System

  • Electronic load share

Lube System

  • Manual sump pump

Mounting

  • Fuel tank base (1200 Ltr)

Special Tests / Reports

  • PGS Test Report @ 1.0 power factor
  • PGS Test Report @ 0.8 power factor
  • Factory Witness Test

Starting / Charging system

  • Battery chargers
  • Battery removal
  • Oversize battery
  • Battery disconnect switch
  • Heavy duty starting system

Enclosures

  • Weather protective enclosure (WP)
  • Sound attenuated enclosure (SA)
  • DC Lighting package

News & Events

View the latest company and product news, events and customer stories.

Promotions

View the latest offers available on a range of Cat® equipment and genuine parts.

Social Media

Connect with us to learn more about our company, products, services and customers.

Branch Locations

With branches across the UK & Ireland, you can be sure that we’re never far away.

Services

Effectively manage your equipment to reduce operating costs and improve efficiency.

Technology

Integrated technology can help you understand your equipment's output and help extend its lifespan.

Finance

Quick and easy financing with customised payment plans through Cat Financial.

Please share your feedback on Finning.com!

Close window

We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

Thank you in advance for your time!