3512 (60 Hz) with Upgradeable Package

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets other NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
  • Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
  • EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
  • Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
  • Certifications

  • UL2200
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
  • EEC Declaration of Conformity
  • One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
  • World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
  • 3512 (60 Hz) with Upgradeable Package Standard Equipment

    Air Inlet System

    • Air cleaner; single element canister type with service indicator

    Control Panel

    • EMCP 4.2
    • Emergency stop pushbutton
    • 24-volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Generator mounted - rear facing
    • Generator set packages include Caterpillar's Voltage Regulator (IVR).
    • IVR includes reactive droop capability, 3-phase voltage sensing
    • KVAR/PF modes, RFI suppression, min/max exciter
    • Limiter and exciter diode monitor
    • Controls:
    • Speed adjust
    • Auto / start / stop control
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning / shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over / under voltage (27/59)
    • Over / under frequency (81 o/u)
    • Reverse power (kW) (32)
    • Reverse reactive power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • 6 programmable digital inputs
    • 4 programmable relay outputs (Form A)
    • 2 programmable relay outputs (Form C)
    • 2 programmable digital outputs

    Cooling System

    • JWAC
    • Fan and belt guards.
    • Coolant drain line with valve
    • Coolant level sensors. (Not included with packages without radiator)
    • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)

    Exhaust

    • Dry Exhaust Manifold
    • Flanged faced outlet(s)

    Fuel System

    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump

    Generators and Attachments

    • 3 Phase brushless, salient pole
    • 6 Lead
    • LV:
    • Random wound
    • Internal excitation or permanent magnet
    • NEMA Class H insulation
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Winding temperature detectors
    • Busbar connections, top center mounted, top cable entry
    • 60 Hz models: NEMA standard hole pattern

    Governing System

    • Woodward 2301A isochronous governor

    Lube System

    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal

    Mounting System

    • Rails - engine/generator/radiator mounting
    • Rubber anti-vibration mounts (shipped loose)

    Starting / Charging System

    • 24-volt electric starting motor
    • 50 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch

    General

    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • RH Service
    • Flywheel and Flywheel housing-SAE No. 00
    • SAE Standard Rotation

    3512 (60 Hz) with Upgradeable Package Optional Equipment

    Air Inlet System

    • Single stage air cleaners
    • Dual element air filters

    Control Panels

    • EMCP 4.2B, EMCP 4.3, EMCP 4.4
    • Vandle proof panel door
    • Modbus monitoring of packages
    • First local annunciator
    • Remote custom annunicator
    • CAN2 Network equipment
    • Cat connect
    • Local discrete I/O package
    • Load share module options

    Cooling System

    • Optional radiator arrangements
    • Water level gauge
    • Coolant

    Exhaust System

    • Industrial grade (15 db) mufflers
    • Exhaust Y adapters
    • Exhaust flexible fitting
    • Exhaust elbows

    Generators and Attachments

    • Space heater
    • Space heater control
    • Generator conversion

    Lube System

    • Lube oil
    • Prelube sump pump
    • Oil level regulator
    • Primary fuel systems

    Special Tests / Reports

    • Generator test report
    • Standard genset TVA report
    • Genset tors vibration analysis
    • Standard engine test charge
    • PKG factory test report
    • PGS test report @ 1.0 power factor
    • Fuel consumption test

    Crankcase System

    • Ventilation system
    • Protection systems

    Batteries and Battery Housing

    • 24 Volt battery set - Dry
    • Battery chargers - 10, 20 and 35 amp

    Mounting System

    • Puck style low efficiency lsolators
    • Spring type vibration isolator

    Select Units

    Overview

    Producing reliable power from 890 to 1250 eKW 60 Hz, our 3512 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 per cent rated load in one step. Generator sets are optimized for low fuel consumption.

    Generator Set Specifications

    • Minimum Rating 890 eKW 890 eKW
    • Maximum Rating 1250 eKW 1250 eKW
    • Emissions/Fuel Strategy Optimized for Low Fuel Consumption Optimized for Low Fuel Consumption
    • Voltage 220 to 13800 Volts 220 to 13800 Volts
    • Frequency 60 Hz 60 Hz
    • Speed 1800 rpm 1800 rpm
    • Duty Cycle Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous

    Engine Specifications

    • Engine Model 3512A, V-12, 4-Stroke Water-Cooled Diesel 3512A, V-12, 4-Stroke Water-Cooled Diesel
    • Bore 6.69 in 170.0 mm
    • Stroke 7.48 in 190.0 mm
    • Displacement 3161.03 in³ 51.8 l
    • Compression Ratio 13.5:1 13.5:1
    • Aspiration TA TA
    • Fuel System MUI MUI
    • Governor Type Woodward Woodward

    Generator Set Dimensions

    • Length - Maximum 203.5 in 5169.0 mm
    • Width - Maximum 79.3 in 2015.0 mm
    • Height - Maximum 92.0 in 2336.0 mm
    • Dry Weight - Genset (minimum) 22099.0 lb 10024.0 kg
    • Dry Weight - Genset (maximum) 22540.0 lb 10224.0 kg
    News & Events

    View the latest company and product news, events and customer stories.

    Promotions

    View the latest offers available on a range of Cat® equipment and genuine parts.

    Social Media

    Connect with us to learn more about our company, products, services and customers.

    Branch Locations

    With branches across the UK & Ireland, you can be sure that we’re never far away.

    Services

    Effectively manage your equipment to reduce operating costs and improve efficiency.

    Technology

    Integrated technology can help you understand your equipment's output and help extend its lifespan.

    Finance

    Quick and easy financing with customised payment plans through Cat Financial.

    Please share your feedback on Finning.com!

    Close window

    We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

    Thank you in advance for your time!