G3512E

G3512E Standard Equipment

Control Panels

  • Kilowatt transducer (ship loose)

Cooling

  • ANSI/DN customer flange connections for JW inlet and outlet
  • Cat flanges on SCAC circuit
  • JW thermostats

Exhaust

  • Dry exhaust manifolds, insulated and shielded
  • Center section cooled turbocharger with Cat flanged outlet
  • Individual exhaust port and turbocharger outlet wired to Integrated Temperature Sensing Module (ITSM) with GECM providing alarms and shutdowns

Fuel system

  • Electronic fuel metering valve
  • Throttle plate, 24V DC actuator, controlled by GECM
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve

Generator

  • SR4B
  • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
  • Reactive droop
  • Bus bar connections
  • Winding temperature detectors
  • Anti-condensation space heater
  • Bearing temperature detectors

Starting/Charging

  • 24V starting motors
  • Battery disconnect switch

General

  • Paint - Caterpillar Yellow except rails and radiators gloss black
  • Crankshaft vibration damper and guard
  • Operation and maintenance manuals
  • Parts book

G3512E Optional Equipment

Air Inlet

  • Air cleaner with precleaner
  • Two element, single-stage air cleaner with enclosure and service indicator

Control Panels

  • Local alarm module
  • Remote annuciator
  • Remote Communications Module (PL1000T, PL1000E)
  • Wall mount EMCP II+

Cooling

  • Inlet/Outlet connections
  • SCAC thermostats

Exhaust

  • Flange
  • Exhaust expander
  • Elbow
  • Flexible fitting

Fuel System

  • Fuel filter
  • Gas pressure regulator
  • Gas shutoff valve 24V, ETR (Energized-To-Run)

Generator

  • Low voltage extension box
  • Cable access box
  • European bus bar

Start/Charging

  • Battery charger
  • Oversized battery
  • Jacket water heater
  • Battery with cable and rack (shipped loose)

General

  • Crankcase explosion relief valve
  • Engine barring group
  • EEC D.O.I and other certifications

Select Units

Overview

From natural gas-fueled combined heat and power (CHP) systems and emergency power for facilities, to renewable biogas energy to support the local grid, or electricity generated from coal mine gases, Caterpillar has a wide range of reliable gas power solutions.

Gas Generator Sets Specification

  • Maximum Continuous Rating 1000 ekW 1000 ekW
  • Fuel Type Natural Gas Natural Gas
  • Maximum Electrical Efficiency 42.20% 42.20%
  • Maximum Standby Rating - -
  • Frequency 50Hz 50Hz
  • RPM 1500 1500

Engine Specifications

  • Aspiration TA TA
  • Bore 6.7 in 170.0 mm
  • Displacement 3158.0 in³ 52.0 l
  • Engine Model G3512E G3512E
  • Stroke 7.5 in 190.0 mm

Generator Set Dimensions

  • Length 181.0 in 4594.0 mm
  • Width 65.0 in 1647.0 mm
  • Height 89.0 in 2255.0 mm
  • Dry Weight - Genset 27475.0 lb 12460.0 kg

Fully protype tested

Field proven in a wide range of apllications worldwide

Certified torsional vibration analysis available

News & Events

View the latest company and product news, events and customer stories.

Promotions

View the latest offers available on a range of Cat® equipment and genuine parts.

Social Media

Connect with us to learn more about our company, products, services and customers.

Branch Locations

With branches across the UK & Ireland, you can be sure that we’re never far away.

Services

Effectively manage your equipment to reduce operating costs and improve efficiency.

Technology

Integrated technology can help you understand your equipment's output and help extend its lifespan.

Finance

Quick and easy financing with customised payment plans through Cat Financial.

Please share your feedback on Finning.com!