Menu

C32 ACERT Tier 2

Select Units

Overview

Producing oil and gas is a complex task that requires equipped designed specifically for the oilfield. Cat C-Series oilfield diesel generator sets offer a rugged design capable of withstanding harsh conditions in the oilfield. Decades of experience in engine manufacturing combined with the latest electronics deliver the highest performance, safe operation, low emissions, and simplified operator interface. Cat generator sets are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. C32 ACERT oilfield diesel generator set. Ratings: 800 - 910 ekW (1000 - 1300 kVA) @ 50 and 60 Hz (1500 and 1800 rpm) meet U.S. EPA Tier 2 equivalent, EU Stage II equivalent emission standards.

Engine Specifications

  • Maximum Rating 800 ekW (1000 kVA) 800 ekW (1000 kVA)
  • Minimum Rating 910 ekW (1300 kVA) 910 ekW (1300 kVA)
  • Emissions/Fuel Strategy U.S. EPA Tier 2 U.S. EPA Tier 2
  • Aspiration Turbocharged-Aftercooled Turbocharged-Aftercooled
  • Manifold Type Dry Dry
  • Bore 5.7 in 145.0 mm
  • Stroke 6.4 in 162.0 mm
  • Displacement 1959.0 in³ 32.1 l
  • Engine Control and Protection ADEM A4 ADEM A4
  • Generator Set Control EMCP 3.1 EMCP 3.1
  • Generator SR4B SR4B
  • Fuel System MEUI MEUI
  • Frequency - Speed 50/60 Hz (1500/1800 rpm) 50/60 Hz (1500/1800 rpm)

Capacity for Liquids

  • Fuel Diesel Diesel

Dimensions

  • Length 206.0 in 5228.0 mm
  • Width 75.0 in 1905.0 mm
  • Height 86.0 in 2180.0 mm
  • Weight 20500.0 lb 9299.0 kg

Product Design

Rugged construction designed to withstand harsh oilfield conditions
Shipped from the factory complete and ready to run
C-Series engines are field-proven in thousands of applications worldwide
Heavy-duty oilfield base designed for load/unload operations in the field
Oversized generators ideal for camp power applications
Heavy-duty, easy to clean cooling system ideal for high ambient temperature operation with no loss of power

EMCP 3.1 Control Panel

EMCP 3.1 offers complete generator set control including engine/generator monitoring, metering, and protection
Segregated low voltage (AC/DC) accessory box provides single point access to accessory connections
Simplified operator interface

C32 ACERT Tier 2 Standard Equipment

Air Inlet System

  • Dual element air cleaner
  • Service indicator

Cooling System

  • Radiator package mounted (50° C)
  • Coolant drain line with valve at edge of base
  • Coolant level sensor
  • Fan and belt guards
  • Coolant level sight gauge
  • Cat Extended Life Coolant
  • Metal top and bottom tanks

Exhaust System

  • Dry exhaust manifold
  • Flange outlets

Fuel System

  • Primary fuel filter with integral water separator
  • Secondary fuel filters
  • Fuel priming pump
  • Flex fuel lines
  • Fuel cooler

Generator

  • SR4B brushless
  • Self excited
  • Class H insulation
  • Form wound
  • IP23 protection
  • Cat DVR 3-phase sensing with selectable volts/Hz
  • 3 sensing CTs and one droop CT
  • Anti-condensation space heater

Generator Attachments

  • Bus bar - NEMA and IEC mechanicallug holes
  • Bottom cable entry; capable of top cable entry

Controls

  • ADEM A4 ECU
  • EMCP 3 Control Panel

Lube System

  • High efficiency oil filter
  • Oil drain valves
  • Fumes disposal
  • Gear-type lube oil pump
  • Deep sump oil pan

Mounting System

  • Steel base frame (skidable)
  • Anti-vibration mounts (shipped loose)
  • Designed welded base for increased durability (I-beam design)

Starting/Charging System

  • 24-volt starting motor
  • 45-amp charging alternator
  • Battery rack
  • Battery disconnect switch
  • Oversized batteries

General

  • Paint — Caterpillar yellow except rails and radiators (gloss black)
  • Flywheel and flywheel housing — SAE No. 0

C32 ACERT Tier 2 Optional Equipment

Air Inlet System

  • Air inlet adapters
  • Precleaners

Exhaust System

  • Stainless steel exhaust flex fittings
  • Elbows, flanges, expanders, and Y adapter

Generator

  • Permanent magnet excitation
  • Oversize and premium generators

Starting/Charging System

  • Jacket water heater with shutoff valves
  • Battery chargers (10 amp)

Controls

  • EMCP 4.2 control panel
  • EMCP 4.3 control panel
  • Local or remote annunciator panel
  • Generator temperature monitoring and protection
  • Discreet I/O module
  • Load share module (optional with direct rack)

News & Events

View the latest company and product news, events and customer stories.

Promotions

View the latest offers available on a range of Cat® equipment and genuine parts.

Social Media

Connect with us to learn more about our company, products, services and customers.

Branch Locations

With branches across the UK & Ireland, you can be sure that we’re never far away.

Services

Effectively manage your equipment to reduce operating costs and improve efficiency.

Technology

Integrated technology can help you understand your equipment's output and help extend its lifespan.

Finance

Quick and easy financing with customised payment plans through Cat Financial.

Please share your feedback on Finning.com!

Close window

We are committed to providing you with the best site experience possible.  Please take our brief survey to tell us how we are doing.

Thank you in advance for your time!