C32 ACERT generator sets incorporate a separate circuit aftercooling system (SCAC) for all configurations. The primary advantage of the SCAC systsem is reduced aftercooler corrosion since no sea water circulates through the aftercooler. Many other improvements on these engines contribute to minimizing owning and operating costs. The EPA Tier 3, IMO II, EU Stage IIIA compliant ratings are available with heat exchanger or keel cooled options. Heat exchanger configurations have an optional front mounted sea water pump.

Compare Models
Generator Set Specifications
expand / collapse icon
Minimum Rating 730 ekW (913 kVA) 730 ekW (913 kVA)
Maximum Rating 940 ekW (1175 kVA) 940 ekW (1175 kVA)
Frequency 60hz 60hz
Speed 1800 rpm 1800 rpm
Emissions/Fuel Strategy EPA Tier III EPA Tier III

Emissions

U.S. EPA Tier 3 compliant

Worldwide Support

Extensive service network of dealers; Unparalleled service from authorized marine dealers

Durability

Proven engine operating history; Performance iron with thousands of hours of validation testing for quality and durability

Reliability

60 months standard warranty

Cooling System

Heat Exchanger or Keel Cooling; Heat exchanger configurations: optional front mounted sea water pump

Aftercooling System

Separate circuit aftercooling system (SCAC): no seawater circulating through the aftercooler

C32 ACERT Tier 3 Standard Equipment

AIR INLET SYSTEM
expand / collapse icon
  • Separate circuit after-cooled (SCAC)
  • Turbocharger, jacket water cooled
  • Turbocharger inlet, 152 mm (6 in) OD straight connection

C32 ACERT Tier 3 Optional Equipment

ALARM AND PROTECTION
expand / collapse icon
  • Remote panels
  • MCS Controller
  • Power analyzer module
  • Oil level, exhaust temperature, air starting pressure, heat exchanger pressure sensors